<LOGO>
FM Transmitter Measurement Report
Created: 2025-10-27 01-48-16
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 54 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 4.9 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 68 kHz 10934 1,0883
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,0 dBr 5,14 dBr 6,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 68 kHz MIN: 11 kHz % above 76 kHz: 1,0883 Acquired: 2025/10/27 1.47.12 Total samples: 10934 Equivalent time: 0:09:06 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 6,0 dBr MIN: 4,0 dBr AVE: 5,14 dBr % above 12,2 dBr: 0,0 Last value: 5,5 dBr (2025/10/27 1.47.12) 01.34 01.36 01.38 01.40 01.42 01.44 01.46 0 2 4 6 Pm [dBr]